Buyer comparison guide · Published 2 November 2026
Put thread coverage on the enquiry line, alongside diameter, pitch and under-head length. A fully threaded hex-head fastener and a partially threaded hex bolt can share those three descriptions while having different shank geometry. Confirm the selected form before comparing quotations.
This guide helps transfer an approved requirement into an RFQ. It does not choose the connection design or establish that either form is suitable for a particular load.
What changes when the length stays the same?
| Enquiry field | Fully threaded form | Partially threaded form |
|---|---|---|
| Form to identify | Full-thread hex-head product. | Hex bolt with an intentional plain shank and threaded end. |
| Length | Keep the specified under-head length and units. | Keep that length separate from the threaded portion. |
| Coverage detail | Retain the governing reference, including its head transition and runout requirements. | Retain the specified thread length, plain-shank dimensions and transition requirements. |
| Quote comparison | Check that a different thread-coverage form has not been offered silently. | Check that the required plain shank is preserved in the proposed part. |
“Full thread” is not a request to remove every transition beneath the head. Equally, “partial thread” is not a complete dimension for the plain section. Use the selected product document or controlled drawing to resolve the geometry.
Keep the reference attached to the form
For the metric coarse-pitch families, ISO 4014:2022 identifies hexagon head bolts and ISO 4017:2022 identifies hexagon head screws. Select the document actually requested; a similar trade name is not permission to substitute a different reference or edition.
Bossard's hexagon screw with shank catalogue entry separately identifies the shank form and marks DIN 931 as withdrawn. A legacy designation on a parts list should therefore trigger clarification of the intended document, not an unrecorded conversion. These references identify families; they do not certify a supplied part.
A manufacturer example also shows why custom coverage needs a drawing: Portland Bolt discusses head style and threading-process limits for its own production. Those limits are specific to that manufacturer. Do not copy them into a different supplier's enquiry or treat a general full-thread label as a capability promise.
Compare two quote lines before comparing prices
Suppose a parts list says only “hex bolt, [thread designation], [length], [quantity].” One quote describes full thread; another describes a plain-shank form. The price lines are not yet a like-for-like comparison. Use this short review:
- Recover the intended form. Check the approved assembly or part drawing and revision. A sample photo can identify a question, but cannot supply an undocumented tolerance.
- Keep shared fields consistent. Match the thread callout, under-head length, units, material/property requirement and finish across the two responses.
- Resolve the differing geometry. Ask which controlled reference defines coverage, plain-shank dimensions and transitions. Request a marked drawing if the description is unclear.
- Record any alternative separately. Keep the requested item and proposed substitution on separate lines until the responsible reviewer accepts the change.
- Close the quotation record. Tie the agreed part description and outstanding checks to the order line before acceptance.
Two blank RFQ descriptions
Use the relevant form below; brackets are fields to complete from approved requirements, not available catalogue sizes.
Full-thread requirement: Hex-head full-thread form; reference/edition or drawing/revision [___]; thread designation [___]; under-head length and units [___]; coverage, runout and end detail per [controlled reference]; material/property [___]; finish [___]; quantity/unit [___]; documents and destination [___]. Please list any proposed deviation separately.
Plain-shank requirement: Partially threaded hex bolt; reference/edition or drawing/revision [___]; thread designation [___]; under-head length and units [___]; threaded portion and plain-shank dimensions per [controlled reference]; transition/end detail [___]; material/property [___]; finish [___]; quantity/unit [___]; documents and destination [___]. Please identify unresolved geometry before quotation acceptance.
If no approved coverage requirement exists, write “coverage to be confirmed” and identify who will resolve it. Do not estimate a shank length from an unscaled photograph or turn a sample reading into a production requirement without review.
Continue with the correct product
Choose fully threaded hex bolts or partially threaded hex bolts for the individual family details. Use the length measurement guide if the length datum is unclear, and the thread specification checklist to complete the callout. Drawing-defined geometry follows the custom enquiry route.
This comparison does not determine shear-plane position, connection capacity, tightening torque or interchangeability. Keep assembly-design decisions with the responsible designer and the applicable controlled requirements.